臨邊護欄的立柱通過膨脹螺栓固定在地面上
來源:http://gdinte.com.cn/ 發(fā)布時間:2022-05-22
臨邊護欄通常安裝在物流通道兩側、生產(chǎn)設備周圍、建筑物角落、門兩側和貨臺邊緣等處,有效減少來回搬運設備時因意外撞擊對設備設施造成的損壞。此外,對物流搬運設備本身也起到保護作用。
Edge guardrails are usually installed on both sides of the logistics channel, around the production equipment, corners of buildings, both sides of doors and the edge of the cargo platform, so as to effectively reduce the damage to equipment and facilities caused by accidental impact when transporting equipment back and forth. In addition, it also protects the logistics handling equipment itself.
在工地上使用臨邊防護欄時,是需要與立柱有一個連接的,但是很多人都不知道連接方法很多人不知道,臨邊防護欄與立柱怎么連接呢?
When the edge guard is used on the construction site, it needs to be connected with the column, but many people don't know the connection method. Many people don't know how to connect the edge guard with the column?
因為安裝方式不正確,安裝不牢固的話也不能使護欄發(fā)揮效果。所以現(xiàn)在我說一下護欄網(wǎng)的安裝方式吧。其實護欄和立柱的連接方式特別的簡單,易操作,安裝時,只需要將護欄的邊耳和立柱的邊耳重合,然后從邊耳的孔隙中打上螺絲安裝固定即可。
Because the installation method is incorrect and the installation is not firm, the guardrail can not play an effect. So now let me talk about the installation method of guardrail. In fact, the connection between the guardrail and the column is particularly simple and easy to operate. During installation, only the side ear of the guardrail and the side ear of the column need to coincide, and then screw in the hole of the side ear for installation and fixation.
施工臨邊應按規(guī)定設置防護欄桿;當開挖深度超過2.0m的,還必須在欄桿式防護基礎上加設密目網(wǎng)防護。防護欄桿應由上、下兩道橫桿及臨邊護欄組成。一般上桿離地面高度為1.0~1.2m;下桿離地面高度為0.5~0.6m;立桿間距不宜大于2.0m。
The construction edge shall be provided with protective railings as required; When the excavation depth exceeds 2.0m, a dense mesh safety net must be added on the basis of railing protection. The protective railing shall be composed of upper and lower cross bars and edge guardrails. Generally, the height of the upper pole from the ground is 1.0 ~ 1.2m; The height of the lower rod from the ground is 0.5 ~ 0.6m; The distance between vertical poles should not be greater than 2.0m.
臨邊護欄離邊口的距離不應小于0,5m,可采用鋼管直接打入地面0.5~0.7m深。當周邊采用板樁或上口有鋼筋混凝土冠梁(壓頂)時,臨邊護欄的鋼管可打在板樁或冠梁(壓頂)外側。
The distance between the edge guardrail and the edge opening shall not be less than 0,5m, and the steel pipe can be directly driven into the ground 0.5 ~ 0.7m deep. When sheet piles are used around or reinforced concrete crown beams (coping) are provided at the upper opening, the steel pipe of the edge guardrail can be driven outside the sheet piles or crown beams (coping).
臨邊護欄的固定及其與上、下橫桿的連接,其整體構造及強度應經(jīng)受1000N外力;若可能有車輛或物體碰撞,則應加大橫桿截面或加密臨邊護欄的間距及埋置深度等措施。
For the fixing of edge guardrail and its connection with upper and lower cross bars, its overall structure and strength shall withstand 1000N external force; If vehicles or objects may collide, measures such as increasing the cross-section of the cross bar or densifying the spacing and embedding depth of the edge guardrail shall be taken.
臨邊護欄的立柱通過膨脹螺栓固定在地面上的相關內容就是這樣了,如果您有更多信息可以來網(wǎng)站gdinte.com.cn分享!
The column of the edge guardrail is fixed on the ground through expansion bolts. If you have more information, please visit gdinte.com.cn Com share!
- 上一篇:彩鋼圍擋安裝前期必做的事情
- 下一篇:pvc圍擋被更多人頻繁使用的原因